Shine Power Panel

Rural India, the agricultural heartland of the country, is plagued by a severe electricity deficit. On the other hand, the country receives enough sunlight in a year. To meet all its energy needs. So, it is not surprising those farmers, industrialists and even housing Societies are switching to solar power as an alternate power source. And, Lobel Solar Systems is leading the way towards a reliable, cost-effective pumping solution that works on solar and regular 3 phase power supply- the Shine Power Panel.




Single Panel Dual supply

The Shine Power Panel offers farmers a range of benefits:

§    Flexibility: Only Standard Power Panel that can operate a pump on both, solar and 3-phase supply.

§    Compatibility: Compatible with surface and submersible pumps as well as Induction and Permanent Magnet Motors.

§    Convenience: Switches between Solar power and 3-phase power automatically or manually.


In-built MPPTè Great savings
The Lobel Solar Systems Shine Power Panel is the only standard AC Panel that offers an in-built Maximum Power Point Tracker (MPPT). It has a range of unique features that can help you save.


§    Maximum power, maximum output: The in-built MPPT helps you extract the maximum available power from the Solar PV, since no extra hardware is required for tracking power Enhanced conversion rate: The conversion from DC input to 3-phase AC takes place even at 300V DC which remains constant irrespective of the drive rating.

§    Increased efficiency: An internal MPPT does not consume any extra power, thereby enhancing the overall efficiency and providing automatic calibration of the maximum power point.


Tough outside è Smart inside
§    Rugged all-weather casing for greater durability.

§    Auto-restart facility.

§    Built-in energy monitoring.

§    Conformal coating to vital components to protect against harsh environment.

§    Complete motor protection.

§    Stores last 10 faults with fault trace for last fault.

§    Provides information on maintenance and remaining life of components.

§    Highly-integrated design results in fewer parts and interconnections, reducing the number of failure points.

§    Plug in cooling fan means easy maintenance.

§    Dry run protection.



Schematic diagram of Shine Power Panel installation





Shine Power Panel Specifications



MPP voltage range (Vmpp)
550-610V












Maximum Open Circuit Voltage (Voc)
800V







Standard






Output Voltage
Proportional to input voltage



Specifications









Output frequency
0 -400 Hz












Over voltage protection
Yes












Short-circuit protection
Yes














Yes



Under voltage protection







Protection

0utput phase loss

Yes












Motor Overheat protection
Yes











Ground Fault protection
Yes












Area of use
Indoor I Outdoor (with Enclosure)









Environmental

Ambient Temperature
-1O to +50oC without deration








tolerances

Humidity
95% RH or less (no condensation)













Altitude
Upto 1000 meters










Standard

RoHS compliant, UL 508C, EN61800-3, EN61800-5-1, EN954-1, ISO 13849-1,

Compliance

IEC/EN61508 SIL2










                      Lobel Solar Power System

“Lobel House” 65 Mihir Park, 
Nr Tube Company, O P Road, 
Vadodara – 20, Gujarat.


                info@lobelpower.com, 

www.lobelpower.com


Comments

  1. You may be qualified for a new government solar energy program.
    Click here and find out if you are qualified now!

    ReplyDelete
  2. Thanks for sharing the useful information. It was really amazing and very informative. Keep sharing more article.
    Solar Panels For Your Home Cost
    Solar Las Vegas

    ReplyDelete

Post a Comment

https://lobelpower.com/

HOTLINE NO 9998931555

Popular posts from this blog

Know the difference between Perc, TOPCon and Heterojunction technology (HJT)....

Solar panel manufacturing technology has come a long way over the years & there have been significant advancements recently with the introduction of mono PERC, Topcon and mainly Heterojunction technology (HJT) technology. These new technologies have led to improvements in solar module efficiency, durability and overall high performance so making them a more viable and cost-effective option for solar PV power generation. Colleagues, Let us know each  solar PV module  technology and understand the differences. 👉💥About PERC Technology : PERC stands for Passivated Emitter & Rear Cell. The PERC solar cell has a presence of a passivation layer at the back side of the cell which helps to minimize recombination losses and increase light absorption.  The key role of the rear-side passivation layer is to reflect light that passes through the silicon cell without being absorbed back into the silicon. By reflecting this light, the passivation layer gives the solar cell seco...

From solar to pump hydro storage - Budget 2024 is for India’s energy transformation.

Lobelsolar -  Energy transition remain a key focus area for the government with solar, nuclear and pump hydro storage getting a policy push with industry experts saying it will provide a major fillip to the capacity addition in the renewables sector. Finance Minister Nirmala Sitharaman said that PM Surya Ghar Muft Bijli Yojana launched in January this year to install rooftop solar plants to enable 1 crore households obtain free electricity up to 300 units every month has received an overwhelming response with more than 1.28 crore registrations and 14 lakh applications. Details showed that the government allocated Rs 8,500.35 crore to solar power (grid), showing a rise of nearly 79% against the revised estimates of the Budget 2023-2024. With an objective to further boost the renewable sector, the government in Union Budget 2024 allocated Rs 19,100 crore to the Ministry of New and Renewable Energy against Rs 12,850 crore allocated in the Interim Budget in February. The revised esti...

Price List of LOBEL Solar POWER Kit ( Except Solar Panel & Inverter )

Our Services Site survey. Customized design solution for solar PV projects. Preliminary design report. 2D & 3D site model. Electrical drawings. MMS design. Shadow analysis report. Detailed project report. Project planner Material procurement support. System integration and commissioning. Operation & maintenance of solar power plants.  TERMS & CONDITIONS: · Price Basis: Ex-stock LOBEL · Tax: As per above Kit table · Fright Charges: Extra as Actual. · Payment Terms: 100 % advance with P.O. · Delivery Period: 3 Days after receipt for PO & Advance