Skip to main content

Lobel Solar Micro Inverter Technology









Output Power:
1200W




Weight:
3.35 KGS




Type:
On Grid Inverter




Recommended Solar :
4x 300Watt




Certificate:
CE, CEC




Working life:
25 Years


Brand Name:
Output Type:
Single
Input Voltage:
22-50V DC
Output Frequency:
50/ 60Hz
Phase type:
Single or 3 Phases
HS code:
8504403090


Model Number:               LSPS1200MG
Size:                              370*306*42mm
Output Voltage:              220V AC
Output Current:              5A
Output waveform:           Pure Sine Wave
Warranty:                       5 year


Solar Power System Stacking use On Grid Tied Power Inverter 1200 Watt


SP 1200W Series Using IP65 waterproof streamline design, Can effectively high performance Maximum Power Point Tracking(MPPT)Function,Better able to track changes in the solar luminosity and control different output power, Effectively capture and collect sunlight. AC electric power transmission using the reverse transmission technology, Is one of our patented technology, the inverter output power can provide load priority use Extra electricity to the grid, efficient use of the inverter to the power emitted, Electricity transmission rate of up to 99%.


 Features



Parameter


Input Data
SP-MG1200-230VAC

  Recommended input power
1200 Watt

  Recommend the use of PV modules
4*300W/Vmp>34V/Voc<50V

  Maximum input DC voltage
50V

  Peak power tracking voltage
25-40V

  Operating Voltage Range
17-50V

  Min / Max start voltage
22-50V

  Maximum DC short current
80A

  Maximum Input Current
54.4A

  
Output Data

@230VAC
  Peak power output

1200Watt
  Rated output power

1150Watt
  Rated output current

5A
  Rated voltage range

180-260VAC
  Rated frequency range

47-52.5Hz
  Power factor

>98%
  Maximum units per branch circuit

5PCS(Single-phase)
  
Output Efficiency

@230VAC
  Static MPPT efficiency

99.50%
  Maximum output efficiency

92%
  Night time power consumption

<70mW Max
  THDI

<5%
  
Exterior

  Ambient temperature
-40°C to +60°C

  Operating temperature range (inverter inside)
-40°C to +82°C

  Dimensions (WxHxD)
370mm*305mm*38mm

  Weight
2.85kg

  Waterproof Rating
IP65

  Cooling
Self-cooling


Feature

  Communication Mode
Power Line

  Power transmission mode
Reverse transfer, load priority

  Monitoring System
Lifetime free

  Electromagnetic compatibility
EN50081.part1EN50082.part1

  Grid disturbance
EN61000-3-2 Safety EN62109

  Grid detection
DIN VDE 1026 UL1741

  Certificate
CEC,CE National patent technology




Lobel Solar System Block Diagram & Application 


In order to achieve higher power, we can use this inverters in stack. For example: 10 pcs ofSPMG1200 1200W grid tie inverters used in stack can achieve 12KW. 
And the stacking number is unlimited.



Easy Installation



Single-phase electrical schematics

Three Phase electrical schematics



Notes:


1. Please install the inverters according to the user manual and connect the ground safety
2. Forbid openning the shell with nonprofessional person, only qualified maintenance person can repair the product.
3. The inverter should be installed in the low humidity and well ventilated place, and remove the flammable things surrounding the inverter for avoiding overheating.
4. Avoid children play when the inverter is working.
5. Ensure the DC input and AC output when connect with PV.
6. The Vmp and Voc of PV should be fit for the Inverter MPPT input voltage forget output max



 Why is the use of micro-inverter?

1.       The transition from a centralized to a distributed inverter optimizes energy collection.

2.       The converter module integrated into the solar panels can reduce installation costs.

3.       By reducing the temperature of the converter and remove the fan, 
       you can enhance system reliability from 5 years to 20 years.

4.     Soft switch technology to replace hardswitching technology can improve efficiency and reduce 
      heat dissipation

5.  From cottage industry to mass production, standardized design (hardware and software) to improve      reliability and reduce costs.

6.      Using a special capacitor (due to the high failure rate). Design requires a higher voltage to reduce        the current, we use a special electrolytic capacitors.

7.    The converter can be connected to the grid to eliminate the need for many battery applications. 
     The high price of batteries, require maintenance, life expectancy is shorter.

8.  Work required microinverter power increasingly smaller (only a few hundred watts), 
     which can reduce the internal temperature and improve reliability.

9.  Microinverter solar inverter system needs to deal with a lot of a particular power level, 
    in order to increase production, thereby reducing costs.


Comments

  1. Thank you for sharing this very valuable information. It is very impressive and very useful blog. I was searching on something on solar inverter, I found your blog very informative with so much or relevant data whom I was searching for, Thank you again for this post.
    Solar inverters South Africa

    ReplyDelete
  2. Excellent information on your thank you for taking the time to share with us!!
    Solar System Manufacturer

    ReplyDelete
  3. Solar power is a modern resource for electricity is it very useful in coming days. This blog is very informative with so much of relevant data whom i was searching for.
    Solar energy in Auckland

    ReplyDelete
  4. great information and the article is quite interesting,now solar energy is emerging and alternative source for production of electrical power,thanks for sharing..

    solar leads


    ReplyDelete

Post a Comment

https://lobelpower.com/

HOTLINE NO 9998931555

Popular posts from this blog

Solar Ongrid Inverter: The Ultimate Guide to Harnessing Solar Power by LobelSolar

Introduction Solar power is rapidly gaining popularity as a clean and sustainable energy source. With the increasing demand for renewable energy solutions, solar  ongrid Ksolare inverters have become a crucial component of solar power systems. In this comprehensive guide, we will explore everything you need to know about solar ongrid inverters, including their functionality, benefits, installation process, and key considerations before making a purchase . Table of Contents What is a Solar Ongrid Inverter? How Does a Solar Ongrid Inverter Work? Types of Solar Ongrid Inverters String Inverters Microinverters Power Optimizers Advantages of Solar Ongrid Inverters Considerations Before Installing System Size and Power Output Efficiency and Performance Grid Compatibility and Regulations Monitoring and Maintenance Warranty and After-Sales Support Steps to Install a Solar Ongrid Inverter Site Assessment and Design Obtaining Necessary Permits Mounting Solar Panels Installing the Solar Ong

Lobel Solar Fencing Machine / ZATKA MACHINE / An Electric Security Fence / 9327007854

DESCRIPTION OF SECURITY FENCING AND ITS  WORKING IN  GENERAL Lobel Security Fencing is the modern day’s alternative to the conventional type of perimeter protection. These are active fences and punish the unwelcome intruder the moment they touches the fence or try to tamper the fence. The conventional types of fences are only passive fences and cannot resist the intruder if they try to forcibly intrude into the protected area. The Security Fence gives a sharp, short but a safe shock and creates psychological fear. Against any tampering the alarm incorporated in the system gets activated and alerts the inmates of the protected area, which facilitates them to counter the unwelcome intruders. The Security Fence is scientific fence and works on Energy with backup facility to run uninterruptedly during the nights as well as cloudy days. The whole system can be derived into two segments, one is the Basic system with CS 250 Unit (Without keypad) and the other one is the Fence. CS 2

Price List of LOBEL Solar POWER Kit ( Except Solar Panel & Inverter )

Our Services Site survey. Customized design solution for solar PV projects. Preliminary design report. 2D & 3D site model. Electrical drawings. MMS design. Shadow analysis report. Detailed project report. Project planner Material procurement support. System integration and commissioning. Operation & maintenance of solar power plants.  TERMS & CONDITIONS: · Price Basis: Ex-stock LOBEL · Tax: As per above Kit table · Fright Charges: Extra as Actual. · Payment Terms: 100 % advance with P.O. · Delivery Period: 3 Days after receipt for PO & Advance